Guangzhou Tabard Fire-Proof Materials Co. Ltd. / Guangzhou Tabard Special Coating Engineering Co. Ltd. 

Details

Home  > PRODUCTS  > Anti-corrosion coatings > Topcoat > Details
F100 Perfluorocarbon Coating with Super-weather Resistance (Two Components)
  • Specifications
    • Product Name:F100 Perfluorocarbon Coating with Super-weather Resistance (Two Components)
    • Product Number:F100
    • 分享到:
  • Details
  • Product Description

    The coating is solvent based coating which is can be cured at room temperature and manufactured by grinding and dispersing fluorine olefin ethyl ether copolymer resin and weather resistance paint, and supplemented by a variety of modified components. The film is tough and rapid drying and good at adhesion, weather resistance and salt fog resistance.


    Design Purpose

    It is used as a finish of high-rise buildings, bridges, offshore platform and all kinds of steel structures.


    Physical Parameters

    Color:

    Various color

     

    Luster

    Glossy, semi-gloss

     

    Theoretical spreading rate

    240g/m2 (calculated by 100μm dry film, excluding loss)

     

    Specific gravity:

    1.26-1.37

     

    Drying time

    23±2℃:surface dry: 0.5h, hard dry: 24h

     

    Entirely cured

    23±2℃:7d

     

    Flash point

    27℃

     

    Storage period

    6 months

    Construction Instruction

    Mixing ratio

    Component A: Component B=9:1


    Maturing time

    23±2℃:20mins


    Service life

    23±2℃:8hs


    Construction method

    High pressure siphon spray and air spray, manual brushing, roller spray and other coating methods.


    Diluent

    X-30 fluorocarbon coating diluent (the amount is commonly 5%-15%).


    Spray orifice

    0.40-0.50mm


    Spray pressure

    250kg/cm2 (spraying information are for reference only and can be adjusted when in practice).


    Tool washing

    X-30 fluorocarbon coating diluent


    Film coating thickness

    170μm for wet film, 100μm for dry film.


    Coating interval

    23±2℃:minimum 2h, maximum 24h


    Surface treatment

    If the preceding paint has been contaminated, take proper measurements to remove grease, dust, and also diluent for the preceding paint can be used to scrub.


    Construction condition

    Temperature is in 5℃ - 35℃, relative humidity shall be less than 85%, surface temperature of the object to be painted shall greater than dew point above 3℃, construction shall be forbidden under the condition of rain, fog, snow and larger dust.

     

    Prior primer

    Zinc-rich epoxy primer, micaceous iron epoxy anti-rusting paint.

     

    Maintenance period

    23±2℃:more than 7d.

    Packing Specification

    Container of 20 liters can load Component A of 18kg, container of 4 liters can load Component B of 2kg.

    Remarks

    Film thickness can be adjusted according to demand, however, that can correspondingly change spreading rate and affect drying time.

    Considerations

    *If coating time of the preceding paint is too long, when coating the sequent paint, roughen the surface with waterproof abrasive paper, paint the coating after clearing away the dust and dirt on the surface to assure the interlayer adhesion.

    *Tools for construction shall be clean and dry, the coating shall not be mixed with water or other impurities, prepare the coating at the time of use, and the coating shall be used up in 4h.

    *Before entirely cured and dry, take protection measurements for the film to avoid the washing and trample from rains or other liquid.

    *Coatings shall be stored in a dry and ventilated place, kept away from heat source, and avoid direct sunshine and isolated from fire.

    Safety guide

    Please pay attention to the security issues on the packaging. In addition, relevant national safety code or specified by the local government shall be followed. Avoid inhaling solvent vapors and spray mist for long term, skin and eye may not contact with the product.

    Forced ventilation shall be provided when applying the paint in confined spaces or stagnant air, although in good ventilation, protection tools shall be worn.

    Annotation

    *Relevant data in this instruction is obtained from laboratory, the actual product may be slightly different from it;

    *If above data is changed, the data is based on the latest instruction, without prior notification.


Tags: