Physical Parameters |
Color: |
Rusty red Gray |
|
Luster |
No gloss |
|
Theoretical spreading rate |
Rusty red:130g/m2, 10m2/L (calculated by 100μm dry, excluding loss)
Gray: 150g/m2, 10m2/L (calculated by 100μm dry, excluding loss) |
|
Specific gravity: |
Rusty red: about 1.32
Gray: about 1.51 |
|
Drying time |
23±2℃:surface dryness≤4h, actual dryness≤24h |
|
Fully cured |
23±2℃:7d |
|
Flash point |
15℃ |
|
Storage period |
12 months |
Construction Instruction |
Mixing ratio |
Rusty red Component A(paint):Component B(curing agent) =25:1.5
Gray Component A(paint):Component B(curing agent) =24:4 |
|
Maturing time |
23 ±2℃:0.5-1h |
|
Service life |
23 ±2℃:8h |
|
Construction method |
High pressure siphon spray,air spray, manual spray, roller spray |
|
Diluent |
Galvanized Plate Special Primer diluent |
|
Maximal dilution amount |
High pressure siphon spray<5%; air spray<10%; manual spray, roller spray<5% |
|
Spray orifice |
High pressure siphon spray0.4~0.5mm; air spray2.0~3.0mm |
|
Spray pressure |
High pressure siphon spray20~30Mpa; air spray0.3~0.4Mpa |
|
Tool washing |
Galvanized Plate Special Primer diluent |
|
Film coating thickness |
Wet film 100μm, dry film 60μm |
|
Coating interval |
Substrate temperature |
5℃ |
20℃ |
30℃ |
|
|
The shortest |
24h |
16h |
8h |
|
|
The longest |
Unlimit |
|
Surface treatment |
The surface of steel material or galvanized plate shall be conducted the process of blasting or sand blasting ,meeting the Swedish derusting standard Sa2.5 level |
|
Construction condition |
The substrate temperature must over 3℃ than usual ,relative humidity shall be less than 85%; when constructional substrate temperature is less than 5℃, construction shall be banned. |
|
Finishing paint |
Epoxy resin paint, epoxy asphalt paint, chlorinated rubber paint, acrylic resin paint, Acrylic resin paint, phenolic resin paint, chlorosulfonated polyethylene paint, high chlorinated polyethylene paint, etc. |
Packing Specification |
Rusty red :Component A:20 liters containers can load 25kg components Component B: 4 liters containers can load 1.5kg components |
|
Gray:Component A:20 liters containers can load 24kg components Component B: 5 liters containers can load 4kg components |
Considerations |
Dry spray phenomenon happened easily in the execution of construction in high temperature season, diluents shall be added, it shall be adjusted to the no sprayed condition. |
Safety guide |
Avoiding inhalation of vapor or mist, skin and eyes shall not be contacted with this product. In the process of construction, the forced ventilation shall be provided especially in the place which is in narrow and stagnant air condition. The protective gear shall be provided in the execution of construction. |
Annotation |
*Above-said thickness of dry film and wet film refers to the index while implementing the high-pressure air-free spray;
*Relevant data in this instruction is obtained from laboratory, the actual product may be slightly different from it;
*If above data is changed, the data is based on the latest instruction, without prior notification. |